This brings advantages in the form of the possibility of additional replacement of cylinder locks or rotary locks with a KWFE electronic code lock.
The integrated cylinder lock performs a combined function. It is used for emergency unlocking of the lock or for unlocking the external panel with a keypad and battery. Battery replacement is a matter of a few seconds, and you will certainly appreciate the fact that you will not need any tools for this operation.
The lock can be programmed conveniently on the removed keypad.
KWFE Lock Parameters
- Numeric keypad
- Optical and acoustic signaling
- Operation on one 1.5V AA alkaline battery
- Depending on the operating mode, up to 100,000 blocking cycles
- Integrated cylinder lock with emergency unlocking or battery access function
- Massive zinc locking mechanism
- 6-digit optional master code
- 4-digit optional user code
- Private and public mode
- AUTO-OPEN-TIMER to prevent blocking by the user in public mode
- Left-hand/right-hand design
KWFE – Private Setting
We recommend using the private setting of the lock if the users of the locker do not change frequently. The user sets their own code and uses it repeatedly until they reset it themselves.
In case of forgetting or losing the code, the lock can be unlocked using a master code or with the key.
KWFE – Public Setting
We recommend using the public setting of the lock if the users of the locker change after each use. The user sets their own code, locks the locker, and when the locker is unlocked again, the previous code is reset and the lock is ready for the next user to enter a new code.
In case of forgetting or losing the code, the lock can be unlocked using a master code or with the key.
We Like
- Well-thought-out design with a number of smart solutions
- Possibility of mounting in standard 16/19 mounting holes
- Possibility of emergency unlocking with a cylinder lock
- Easy battery replacement without tools
- Convenient programming on the dismounted external part of the lock